<< Back to Case History

End User/Client
 
  Sydney Water/Bovis-Tenix
   
Location
 

Sydney, Australia

 

Description of works

Sewer rehabilitation of 900mm and 1200mm diameter steel pipes
Abrasive blasting and epoxy lining of 500 lineal meters of pipe
   
Project Period      
  Oct 2000 - March 2001  
       
Project Details    

The work included epoxy lining, injection grouting of sewer leaks and repairs to corroded sewer sections. The project required the use of various chemicals ranging from epoxies, polyurethanes and cementitious products. This called for applicators with wide ranging experience in resin technologies, applying all materials.

The work was completed in sewer diameters as small as 900mm, this required careful planning, safety training and preparation of procedures, including confined space, ventilation and multiple sentries located inside and outside the pipe amongst other safety measures.
 

 
<< back to case history | top